Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 25.702
Filtrar
1.
JBJS Rev ; 12(4)2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38619394

RESUMO

¼ Identification of malnourished and at-risk patients should be a standardized part of the preoperative evaluation process for every patient.¼ Malnourishment is defined as a disorder of energy, protein, and nutrients based on the presence of insufficient energy intake, weight loss, muscle atrophy, loss of subcutaneous fat, localized or generalized fluid accumulation, or diminished functional status.¼ Malnutrition has been associated with worse outcomes postoperatively across a variety of orthopaedic procedures because malnourished patients do not have a robust metabolic reserve available for recovery after surgery.¼ Screening assessment and basic laboratory studies may indicate patients' nutritional risk; however, laboratory values are often not specific for malnutrition, necessitating the use of prognostic screening tools.¼ Nutrition consultation and perioperative supplementation with amino acids and micronutrients are 2 readily available interventions that orthopaedic surgeons can select for malnourished patients.


Assuntos
Desnutrição , Procedimentos Ortopédicos , Ortopedia , Humanos , Estado Nutricional , Procedimentos Ortopédicos/efeitos adversos , Suplementos Nutricionais
2.
IEEE J Transl Eng Health Med ; 12: 340-347, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38606389

RESUMO

OBJECTIVE: Cemented total hip arthroplasty (THA) demonstrates superior survival rates compared to uncemented procedures. Nevertheless, most younger patients opt for uncemented THA, as removing well-fixed bone cement in the femur during revisions is complex, particularly the distal cement plug. This removal procedure often increases the risk of femoral fracture or perforation, haemorrhage and weakening bone due to poor drill control and positioning. Aim of this study was to design a novel drill guide to improve drill positioning. METHODS AND PROCEDURES: A novel orthopaedic drill guide was developed, featuring a compliant centralizer activated by a drill guide actuator. Bone models were prepared to assess centralizing performance. Three conditions were tested: drilling without guidance, guided drilling with centralizer activation held, and guided drilling with centralizer activation released. Deviations from the bone centre were measured at the entry and exit point of the drill. RESULTS: In the centralizing performance test, the drill guide significantly reduced drill hole deviations in both entry and exit points compared to the control ([Formula: see text]). The absolute deviation on the exit side of the cement plug was 10.59mm (SD 1.56) for the 'No drill guide' condition, 3.02mm (SD 2.09) for 'Drill guide - hold' and 2.12mm (SD 1.71) for 'Drill guide - release'. The compliant drill guide centralizer significantly lowered the risk of cortical bone perforation during intramedullary canal drilling in the bone models due to better control of the cement drill position. Clinical and Translational Impact Statement: The drill guide potentially reduces perioperative risks in cemented femoral stem revision. Future research should identify optimal scenarios for its application.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Ortopedia , Humanos , Artroplastia de Quadril/efeitos adversos , Reoperação , Fêmur/cirurgia , Cimentos Ósseos/uso terapêutico
3.
J Orthop Surg Res ; 19(1): 234, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38610023

RESUMO

BACKGROUND: Contiguous two-segment cervical disc arthroplasty (CDA) is safe and effective, while post-operative radiographic change is poorly understood. We aimed to clarify the morphological change of the three vertebral bodies operated on. METHODS: Patients admitted between 2015 and 2020 underwent contiguous two-level Prestige LP CDA were included. The follow-up was divided into immediate post-operation (≤ 1 week), early (≤ 6 months), and last follow-up (≥ 12 months). Clinical outcomes were measured by Japanese Orthopedic Association (JOA) score, visual analogue score (VAS), and neck disability index (NDI). Radiographic parameters on lateral radiographs included sagittal area, anterior-posterior diameters (superior, inferior endplate length, and waist length), and anterior and posterior heights. Sagittal parameters included disc angle, Cobb angle, range of motion, T1 slope, and C2-C7 sagittal vertical axis. Heterotopic ossification (HO) and anterior bone loss (ABL) were recorded. RESULTS: 78 patients were included. Clinical outcomes significantly improved. Of the three operation-related vertebrae, only middle vertebra decreased significantly in sagittal area at early follow-up. The four endplates that directly meet implants experienced significant early loss in length. Sagittal parameters were kept within an acceptable range. Both segments had a higher class of HO at last follow-up. More ABL happened to middle vertebra. The incidence and degree of ABL were higher for the endplates on middle vertebra only at early follow-up. CONCLUSION: Our findings indicated that after contiguous two-segment CDA, middle vertebra had a distinguishing morphological changing pattern that could be due to ABL, which deserves careful consideration before and during surgery.


Assuntos
Doenças Ósseas Metabólicas , Ortopedia , Humanos , Artroplastia/efeitos adversos , Coluna Vertebral , Corpo Vertebral
4.
ANZ J Surg ; 94(4): 724-732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572937

RESUMO

INTRODUCTION: Surgical glove perforation has been linked to a double-fold increased risk of surgical site infection. Infection in the context of arthroplasty can have devastating consequences. In orthopaedics, use of polymethyl methacrylate (PMMA) bone cement is commonplace, and the impact on glove strength and perforation risk is not fully understood. This study aimed to examine the resistance to perforation and thickness of gloves following PMMA exposure, in accordance with the International Organization for Standardization (ISO) standard for glove integrity. METHODS: Pairs of gloves were separated and randomly sorted into exposure and control groups. Twenty pairs of latex and 40 pairs of polyisoprene gloves were used. Exposure group glove cuffs were in contact with cement from a single surface of the glove for 13 min as cement cured. Force to perforation and glove thickness were tested in accordance with ISO guidelines. RESULTS: Latex gloves were found to have a significantly increased force to perforation following PMMA exposure (10.26 Newtons (N) vs. 9.81 N, P = 0.048). Both polyisoprene under- and over-gloves were shown to have no significant change in strength to perforation post exposure (9.69 N vs. 9.83 N, P = 0.561, and 10.26 N vs. 10.65 N, P = 0.168, respectively). All groups were over the ISO standard minimum strength of 5 N. CONCLUSIONS: Exposure of latex and polyisoprene surgical gloves to PMMA bone cement does not appear to increase glove perforation risk and rather may improve natural rubber latex glove strength. This study supports the use of latex and polyisoprene surgical gloves in procedures that involve the handling of PMMA bone cement.


Assuntos
Luvas Cirúrgicas , Ortopedia , Humanos , Polimetil Metacrilato/efeitos adversos , Cimentos Ósseos/efeitos adversos , Látex
5.
Medicine (Baltimore) ; 103(15): e37714, 2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38608113

RESUMO

BACKGROUND: The coronavirus disease-2019 (COVID-19) pandemic has had a dramatic impact on global health, with orthopedics among the most affected specialties. An increasing number of COVID-19-related orthopedic studies have been published. The purpose of this study was to analyze the orthopedic literature published during the COVID-19 pandemic to guide future research. METHODS: The Scopus database was searched for relevant literature published between 2020 and 2022. The keywords used in the retrieval process were ("COVID-19" OR "Coronavirus" OR "2019-nCoV" OR "SARS-CoV-2" OR "Betacoronavirus" OR "novel coronavirus 2019" OR "novel coronavirus" OR "coronavirus-19" OR "COVID 19" OR "nCOV" OR "COVID-2019" OR "COVID 2019") and ("orthopedic" OR "orthopedics" OR "orthopedic" OR "orthopedical" OR "orthopedical" OR "orthopedics"). Spreadsheet software (Excel, Microsoft Corp., Redmond, WA) was used to analyze the top 10 cited authors, countries, journals, and articles. The top 5 publication types were also analyzed. VOSviewer (Center for Science and Technology Studies, Leiden, Netherlands) was used to network and visualize the literature. RESULTS: A total of 1619 publications relevant to COVID-19 and orthopedics were reviewed. Among these publications, the most active country, author, and publication type included the United States, Vaishya R, and original articles, respectively. The most frequently used keywords were human, coronavirus disease-2019, pandemic, and orthopedics. The Journal of Bone and Joint Surgery American Volume was the most cited journal, whereas the greatest number of articles was published in the Journal of Clinical Orthopedics and Trauma. CONCLUSIONS: This study provides a perspective on the development of orthopedic publications during the COVID-19 pandemic and evidence for researchers worldwide to strengthen global cooperation in fighting the epidemic.


Assuntos
COVID-19 , Procedimentos Ortopédicos , Ortopedia , Humanos , COVID-19/epidemiologia , Pandemias , SARS-CoV-2 , Bibliometria
6.
S Afr J Surg ; 62(1): 7-13, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38568119

RESUMO

BACKGROUND: Globally, medical institutes have seen an increase in female graduates, however surgical disciplines remain male-dominated. An epidemiological shift towards non-communicable diseases and trauma may result in a shortage of surgical specialists. One strategy to improve the surgical workforce is the recruitment of female graduates. METHODS: A non-validated questionnaire was administered to females registered for the Master of Medicine (MMED) degree in General and Orthopaedic Surgery at the University of KwaZulu-Natal (UKZN) between 2000 and 2015. The study evaluated reasons for choice of surgery as a career, challenges faced on the domestic and work front, as well as factors that assisted with successful completion of training. RESULTS: Seventy-two female trainees in General Surgery and Orthopaedics were identified from the UKZN databases. The contact details for 62 of these trainees were available. The overall response rate was 71.0% (44/62). A total of 95.5% (42/44) of participants selected surgery due to a passion for the field. Major challenges identified were a poor home and work-life balance (72.1%, 31/43) and poor working conditions (62.8%, 27/43). Female trainees perceived that they were viewed as inferior by patients (65.9%, 29/44). Successful trainees had a good home support system (89.3%, 25/28) and mentorship during training (60.7%, 17/28), and 85.7% (24/28) did not regret their career choice. CONCLUSION: The recruitment and retention of females in surgery will contribute to maintaining an adequate surgical workforce. Training programmes need to improve work-life balance without compromising on producing competent surgeons. Improved visibility of female surgeons in leadership roles should be encouraged to promote mentorship and recruitment of trainees.


Assuntos
Procedimentos Ortopédicos , Ortopedia , Humanos , Feminino , Masculino , África do Sul , Escolha da Profissão , Bases de Dados Factuais
7.
J Orthop Surg Res ; 19(1): 213, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38561788

RESUMO

BACKGROUND: The application of lower limb traction during hip arthroscopy and femur fractures osteosynthesis is commonplace in orthopaedic surgeries. Traditional methods utilize a perineal post on a traction table, leading to soft tissue damage and nerve neuropraxia. A postless technique, using high-friction pads, has been considered as a potential damage-free alternative. However, whether these pads sufficiently prevent patient displacement remains unknown. Thus, this study systematically assesses the efficacy of commercial high-friction pads (PinkPad and CarePad) in restraining subject displacement, for progressively increasing traction loads and different Trendelenburg angles. METHODS: Three healthy male subjects were recruited and tested in supine and Trendelenburg positions (5° and 10°), using a customized boot-pulley system. Ten load disks (5 kg) were dropped at 15s intervals, increasing gradually the traction load up to 50 kg. Pelvis displacement along the traction direction was measured with a motion capture system. The displacement at 50 kg of traction load was analyzed and compared across various pads and bed inclinations. Response to varying traction loads was statistically assessed with a quadratic function model. RESULTS: Pelvis displacement at 50 kg traction load was below 60 mm for all conditions. Comparing PinkPad and CarePad, no significant differences in displacement were observed. Finally, similar displacements were observed for the supine and Trendelenburg positions. CONCLUSIONS: Both PinkPad and CarePad exhibited nearly linear behavior under increasing traction loads, limiting displacement to 60 mm at most for 50 kg loads. Contrary to expectations, placing subjects in the Trendelenburg position did not increase adhesion.


Assuntos
Ortopedia , Humanos , Masculino , Tração/métodos , Articulação do Quadril/cirurgia , Pelve , Fixação Interna de Fraturas
8.
Front Public Health ; 12: 1327934, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38596512

RESUMO

Opioids are vital to pain management and sedation after trauma-related hospitalization. However, there are many confounding clinical, social, and environmental factors that exacerbate pain, post-injury care needs, and receipt of opioid prescriptions following orthopaedic trauma. This retrospective study sought to characterize differences in opioid prescribing and dosing in a national Medicaid eligible sample from 2010-2018. The study population included adults, discharged after orthopaedic trauma hospitalization, and receiving an opioid prescription within 30 days of discharge. Patients were identified using the International Classification of Diseases (ICD-9; ICD-10) codes for inpatient diagnosis and procedure. Filled opioid prescriptions were identified from National Drug Codes and converted to morphine milligram equivalents (MME). Opioid receipt and dosage (e.g., morphine milligram equivalents [MME]) were examined as the main outcomes using regressions and analyzed by year, sex, race/ethnicity, residence rurality-urbanicity, and geographic region. The study population consisted of 86,091 injured Medicaid-enrolled adults; 35.3% received an opioid prescription within 30 days of discharge. Male patients (OR = 1.12, 95% CI: 1.07-1.18) and those between 31-50 years of age (OR = 1.15, 95% CI: 1.08-1.22) were found to have increased odds ratio of receiving an opioid within 30 days of discharge, compared to female and younger patients, respectively. Patients with disabilities (OR = 0.75, 95% CI: 0.71-0.80), prolonged hospitalizations, and both Black (OR = 0.87, 95% CI: 0.83-0.92) and Hispanic patients (OR = 0.72, 95% CI: 0.66-0.77), relative to white patients, had lower odds ratio of receiving an opioid prescription following trauma. Additionally, Black and Hispanic patients received lower prescription doses compared to white patients. Individuals hospitalized in the Southeastern United States and those between the ages of 51-65 age group were found to be prescribed lower average daily MME. There were significant variations in opioid prescribing practices by race, sex, and region. National guidelines for use of opioids and other pain management interventions in adults after trauma hospitalization may help limit practice variation and reduce implicit bias and potential harms in outpatient opioid usage.


Assuntos
Analgésicos Opioides , Endrin/análogos & derivados , Ortopedia , Adulto , Estados Unidos/epidemiologia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Recém-Nascido , Analgésicos Opioides/uso terapêutico , Analgésicos Opioides/efeitos adversos , Estudos Retrospectivos , Medicaid , Padrões de Prática Médica , Alta do Paciente , Derivados da Morfina
9.
Acta Orthop ; 95: 152-156, 2024 Mar 21.
Artigo em Inglês | MEDLINE | ID: mdl-38597205

RESUMO

BACKGROUND AND PURPOSE: Large language models like ChatGPT-4 have emerged. They hold the potential to reduce the administrative burden by generating everyday clinical documents, thus allowing the physician to spend more time with the patient. We aimed to assess both the quality and efficiency of discharge documents generated by ChatGPT-4 in comparison with those produced by physicians. PATIENTS AND METHODS: To emulate real-world situations, the health records of 6 fictional orthopedic cases were created. Discharge documents for each case were generated by a junior attending orthopedic surgeon and an advanced orthopedic resident. ChatGPT-4 was then prompted to generate the discharge documents using the same health record information. The quality assessment was performed by an expert panel (n = 15) blinded to the source of the documents. As secondary outcome, the time required to generate the documents was compared, logging the duration of the creation of the discharge documents by the physician and by ChatGPT-4. RESULTS: Overall, both ChatGPT-4 and physician-generated notes were comparable in quality. Notably, ChatGPT-4 generated discharge documents 10 times faster than the traditional method. 4 events of hallucinations were found in the ChatGPT-4-generated content, compared with 6 events in the human/physician produced notes. CONCLUSION:  ChatGPT-4 creates orthopedic discharge notes faster than physicians, with comparable quality. This shows it has great potential for making these documents more efficient in orthopedic care. ChatGPT-4 has the potential to significantly reduce the administrative burden on healthcare professionals.


Assuntos
Cirurgiões Ortopédicos , Ortopedia , Humanos , Projetos Piloto , Alta do Paciente , Pessoal de Saúde
11.
Acta Orthop ; 95: 180-185, 2024 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-38629944

RESUMO

BACKGROUND AND PURPOSE: Efficient abstract scoring for congress presentation is important. Given the emergence of new study methodologies, a scoring system that accommodates all study designs is warranted. We aimed to assess the equivalence of a simplified, 2-question abstract grading system with a more complex currently used system in assessing abstracts submitted for orthopedic scientific meetings in a serial randomized study. METHODS: Dutch Orthopedic Association Scientific Committee (DOASC) members were randomized to grade abstracts using either the current grading system, which includes up to 7 scoring categories, or the new grading system, which consists of only 2 questions. Pearson correlation coefficient and mean abstract score with 95% confidence intervals (CI) were calculated. RESULTS: Analysis included the scoring of 195 abstracts by 12-14 DOASC members. The average score for an abstract using the current system was 60 points (CI 58-62), compared with 63 points (CI 62-64) using the new system. By using the new system, abstracts were scored higher by 3.3 points (CI 1.7-5.0). Pearson correlation was poor with coefficient 0.38 (P < 0.001). CONCLUSION: The simplified abstract grading system exhibited a poor correlation with the current scoring system, while the new system offers a more inclusive evaluation of varying study designs and is preferred by almost all DOASC members.


Assuntos
Ortopedia , Humanos , Distribuição Aleatória , Correlação de Dados , Projetos de Pesquisa
13.
PLoS One ; 19(4): e0300662, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38630758

RESUMO

PURPOSE: To explore the feasibility and validity of machine learning models in determining causality in medical malpractice cases and to try to increase the scientificity and reliability of identification opinions. METHODS: We collected 13,245 written judgments from PKULAW.COM, a public database. 963 cases were included after the initial screening. 21 medical and ten patient factors were selected as characteristic variables by summarising previous literature and cases. Random Forest, eXtreme Gradient Boosting (XGBoost) and Light Gradient Boosting Machine (LightGBM) were used to establish prediction models of causality for the two data sets, respectively. Finally, the optimal model is obtained by hyperparameter tuning of the six models. RESULTS: We built three real data set models and three virtual data set models by three algorithms, and their confusion matrices differed. XGBoost performed best in the real data set, with a model accuracy of 66%. In the virtual data set, the performance of XGBoost and LightGBM was basically the same, and the model accuracy rate was 80%. The overall accuracy of external verification was 72.7%. CONCLUSIONS: The optimal model of this study is expected to predict the causality accurately.


Assuntos
Imperícia , Ortopedia , Humanos , Reprodutibilidade dos Testes , China , Aprendizado de Máquina
16.
BMJ Open ; 14(4): e076107, 2024 Apr 10.
Artigo em Inglês | MEDLINE | ID: mdl-38604638

RESUMO

OBJECTIVES: Clinical practice guideline (CPG) developers conduct systematic summaries of research evidence, providing them great capacity and ability to identify research priorities. We systematically analysed the reporting form and content of research priorities in CPGs related to knee osteoarthritis (KOA) to provide a valuable reference for guideline developers and clinicians. DESIGN: A methodological literature analysis was done and the characteristics of the reporting form and the content of the research priorities identified in KOA CPGs were summarised. DATA SOURCES: Six databases (PubMed, Embase, China National Knowledge Infrastructure, VIP Database for Chinese Technical Periodicals, Wanfang and Chinese Biomedical Literature Database) were searched for CPGs published from 1 January 2017 to 4 December 2022. The official websites of 40 authoritative orthopaedic societies, rheumatology societies and guideline development organisations were additionally searched. ELIGIBILITY CRITERIA: We included all KOA CPGs published in English or Chinese from 1 January 2017 that included at least one recommendation for KOA. We excluded duplicate publications, older versions of CPGs as well as guidance documents for guideline development. DATA EXTRACTION AND SYNTHESIS: Reviewers worked in pairs and independently screened and extracted the data. Descriptive statistics were used, and absolute frequencies and proportions of related items were calculated. RESULTS: 187 research priorities reported in 41 KOA CPGs were identified. 24 CPGs reported research priorities, of which 17 (41.5%) presented overall research priorities for the entire guideline rather than for specific recommendations. 110 (58.8%) research priorities were put forward due to lack of evidence. Meanwhile, more than 70% of the research priorities reflected the P (population) and I (intervention) structural elements, with 135 (72.2%) and 146 (78.1%), respectively. More than half of the research priorities (118, 63.8%) revolved around evaluating the efficacy of interventions. Research priorities primarily focused on physical activity (32, 17.3%), physical therapy (30, 16.2%), surgical therapy (27, 14.6%) and pharmacological treatment (26, 14.1%). CONCLUSIONS: Research priorities reported in KOA CPGs mainly focused on evaluating non-pharmacological interventions. There exists considerable room for improvement for a comprehensive and standardised generation and reporting of research priorities in KOA CPGs.


Assuntos
Ortopedia , Osteoartrite do Joelho , Humanos , Osteoartrite do Joelho/terapia , Publicações , Pesquisa , Bases de Dados Factuais
17.
Arch Osteoporos ; 19(1): 24, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38565791

RESUMO

A survey of awareness and attitudes to the management of fragility fractures among the membership of the Asia Pacific Orthopaedic Association conducted in 2022 found considerable variation in care across the region. A Call to Action is proposed to improve acute care, rehabilitation and secondary fracture prevention across Asia Pacific. PURPOSE: Fragility fractures impose a substantial burden on older people and their families, healthcare systems and national economies. The current incidence of hip and other fragility fractures across the Asia Pacific region is enormous and set to escalate rapidly in the coming decades. This publication describes findings of a survey of awareness and attitudes to the management of fragility fractures among the membership of the Asia Pacific Orthopaedic Association (APOA) conducted in 2022. METHODS: The survey was developed as a collaboration between the Asia Pacific Osteoporosis and Fragility Fracture Society and the Asia Pacific Fragility Fracture Alliance, and included questions relating to aspects of care upon presentation, during surgery and mobilisation, secondary fracture prevention, and access to specific services. RESULTS: In total, 521 APOA members completed the survey and marked variation in delivery of care was evident. Notable findings included: Fifty-nine percent of respondents indicated that analgesia was routinely initiated in transit (by paramedics) or within 30 minutes of arrival in the Emergency Department. One-quarter of respondents stated that more than 80% of their patients underwent surgery within 48 hours of admission. One-third of respondents considered non-hip, non-vertebral fractures to merit assessment of future fracture risk. One-third of respondents reported the presence of an Orthogeriatric Service in their hospital, and less than a quarter reported the presence of a Fracture Liaison Service. CONCLUSION: A Call to Action for all National Orthopaedic Associations affiliated with APOA is proposed to improve the care of fragility fracture patients across the region.


Assuntos
Ortopedia , Fraturas por Osteoporose , Humanos , Idoso , Fraturas por Osteoporose/epidemiologia , Fraturas por Osteoporose/prevenção & controle , Ásia/epidemiologia , Inquéritos e Questionários , Apolipoproteínas A
18.
Zhongguo Gu Shang ; 37(2): 114-119, 2024 Feb 25.
Artigo em Chinês | MEDLINE | ID: mdl-38425059

RESUMO

OBJECTIVE: To explore and compare the clinical efficacy of orthopedic robot assisted femoral neck system (FNS) and traditional manual FNS in the treatment of femoral neck fractures in middle-aged and young people. METHODS: The clinical data of 62 consecutive patients with femoral neck fracture and age less than 65 years old admitted to the Intelligent Orthopaedic Department of Beijing Jishuitan Hospital from June 2021 to June 2022 were retrospectively analyzed. According to whether orthopedic robot-assisted surgery the patients were divided into two groups:30 patients aged 34 to 56 years old were treated with orthopedic robot assisted FNS internal fixation after closed or limited open reduction(experimental group); 32 patients aged 33 to 54 years old underwent FNS internal fixation after closed or limited open reduction(control group). The age, gender, time from injury to admission, average hospital stay, surgical duration, intraoperative bleeding volume, and intraoperative fluoroscopy frequency of two groups of patients were analyzed and compared. The hip joint function in both groups of patients was evaluated using the Harris hip joint scoring standard at 6 months after surgery. RESULTS: All 62 patients with femoral neck fractures successfully completed the surgery. There was no significant difference(P>0.05) between the experimental group and the control group in terms of baseline data such as age, gender, time from injury to admission, time from admission to surgery and the intraoperative bleeding. The surgical duration of the experimental group was significantly shorter than that of the control group [42.1(28.5, 50.7)min vs. 53.4(36.9, 62.5) min, Z=-2.338, P=0.019]. The intraoperative X-ray fluoroscopy frequency of the experimental group was significantly lower than that of the control group[8.0 (6.0, 11.0) times vs. 15.0(13.0, 17.0) times, Z=-5.960, P<0.001]. In terms of postoperative hip joint function, there was no significant difference in Harris score between the two groups of patients at 6-month follow-up(P>0.05). CONCLUSION: Compared with manual operation of FNS, orthopedic robot assisted FNS in the treatment of femoral neck fractures can help shorten surgical time, reduce intraoperative fluoroscopy frequency, and have similar therapeutic effects on long-term hip joint function recovery.


Assuntos
Fraturas do Colo Femoral , Ortopedia , Robótica , Pessoa de Meia-Idade , Humanos , Adolescente , Idoso , Adulto , Colo do Fêmur , Estudos Retrospectivos , Fraturas do Colo Femoral/cirurgia , Resultado do Tratamento , Fixação Interna de Fraturas
19.
Zhongguo Gu Shang ; 37(2): 119-23, 2024 Feb 25.
Artigo em Chinês | MEDLINE | ID: mdl-38425060

RESUMO

OBJECTIVE: To investigate the preliminary clinical effect of closed reduction and cannulated nail internal fixation for femoral neck fracture assisted by robot navigation and positioning system. METHODS: From July 2019 to January 2020, 16 cases of femoral neck fracture (navigation group) were treated with closed reduction and internal fixation guided by robot system, including 7 males and 9 females, aged 25 to 72 years old with an average of (53.61±5.45) years old;Garden classification of fracture:3 cases of typeⅠ, 3 cases of typeⅡ, 8 cases of type Ⅲ, 2 cases of type Ⅳ. Non navigation group (control group):20 cases of femoral neck fracture were treated with closed reduction and hollow nail internal fixation, 8 males and 12 females, aged 46 to 70 years old with an average of (55.23±4.64) years old;Garden typeⅠin 2 cases, typeⅡin 4 cases, type Ⅲ in 11 cases, type Ⅳ in 3 cases. The operation time, fluoroscopy times, guide needle drilling times, screw adjustment times, intraoperative bleeding volume and other indicators of two groups were evaluated. RESULTS: Both groups were followed up for 12 to 18 months with an average of (15.6±2.8) months. The fractures of both groups were healed without delayed union and nonunion. There was no significant difference in healing time between two groups(P=0.782). There was no significant difference in Harris scores between two groups at the last follow-up(P=0.813). There was no significant difference in operation time between two groups(P>0.05). There were significant differences between two groups in fluoroscopy times, guide needle drilling times, hollow screw replacement times, and intraoperative bleeding volume(P<0.05). CONCLUSION: Closed reduction and hollow screw internal fixation assisted by robot navigation system for femoral neck fracture has the advantages of minimally invasive operation, precise screw placement, and reduction of X-ray radiation damage during operation.


Assuntos
Fraturas do Colo Femoral , Ortopedia , Robótica , Masculino , Feminino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Resultado do Tratamento , Fraturas do Colo Femoral/cirurgia , Parafusos Ósseos , Fixação Interna de Fraturas , Consolidação da Fratura , Estudos Retrospectivos
20.
Zhongguo Gu Shang ; 37(2): 129-34, 2024 Feb 25.
Artigo em Chinês | MEDLINE | ID: mdl-38425062

RESUMO

OBJECTIVE: To compare the effectiveness of TiRobot assisted F screw technique and inverted triangle parallel nail internal fixation in the treatment of unstable femoral neck fractures. METHODS: A retrospective analysis was conducted on 72 patients with unstable femoral neck fractures who were treated with percutaneous cannulated screw fixation assisted with TiRobot Orthopaedic robot from December 2019 to April 2021. Among them, 37 patients were treated with F screw internal fixation, including 16 males and 21 females, aged 47 to 64 years old with an average of (53.87±5.28) years old;According to Pauwels classification, there were 1 case of type Ⅰ, 19 cases of type Ⅱ, 17 cases of type Ⅲ;8 cases of combined medical diseases;17 cases of falling, 8 cases of traffic accident and 12 cases of falling from height;The time from injury to operation was 29 to 49 hours with average of (35.00±7.34) hours. Another 35 cases used internal fixation with an inverted triangle parallel nail, including 13 males and 22 females with an average age of 46 to 63 years old (52.36±5.05) years old;According to the Pauwels injury classification:there were 2 cases of type Ⅰ, 21 cases of type Ⅱ, 12 cases of type Ⅲ;6 cases of medical diseases, 15 cases of falling injury, 9 cases of traffic accident, 11 cases of falling injury;The time from injury to operation was 30 to 45 hours with an average of (33.00±6.83) h. The intraoperative blood loss, operation time, intraoperative fluoroscopy times, follow-up time, fracture healing time, postoperative complications were observed and compared between the two groups. The hip joint function was evaluated by Harris score at 6 months and 12 months after operation. RESULTS: There was no significant difference in operation time, intraoperative blood loss, intraoperative fluoroscopy times and other intraoperative data between two groups(P>0.05). Both groups were followed up regularly, and the follow-up time was 12 to 16 months. The fracture healing time and Harris score of the F screw internal fixation group were better than those of the inverted triangle parallel nail internal fixation group (P<0.05). There was 1 case of femoral neck shortening in the F screw internal fixation group, 1 case of nonunion, 1 case of nail withdrawal, and 1 case of lower extremity deep vein thrombosis in the inverted triangle internal fixation group. The incidence of complications in the F screw internal fixation group was lower than that in the inverted triangle parallel nail internal fixation group(P<0.05). CONCLUSION: Percutaneous cannulated F screw technique using Tirobot navigation positioning system is a safe and effective treatment for patients with unstable femoral neck fractures. It can significantly shorten the fracture healing time, reduce the incidence of postoperative complications, significantly improve hip joint function, and improve the quality of life.


Assuntos
Fraturas do Colo Femoral , Ortopedia , Robótica , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Perda Sanguínea Cirúrgica , Estudos Retrospectivos , Qualidade de Vida , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Parafusos Ósseos , Resultado do Tratamento , Complicações Pós-Operatórias
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...